The evidence behind long-duration rhythm monitoring.

Rhythm problems come and go, and many cause no symptoms, so a short ECG often misses them. Here is what our monitored cohort shows, what we have published, and the literature behind every claim we make, including where it falls short.

AF detected, by length of recording

Share of atrial fibrillation detected by recordings of different lengths, against three years of continuous monitoring
Recording lengthAF detected
10 s1.5%
24 h11%
48 h13%
72 h15%
7 days21%
30 days34%
Against three years of continuous implantable monitoring, in the same people. Diederichsen SZ et al., Circulation, 2020.

Impact

1 in 4 patients we monitored had a finding that changed what happened next.

Observations from the cohort analysed on the platform, and the patients behind them.

  • 59,297

    patients in the analysed monitored cohort

  • 1 in 4

    had a critical or significant finding

  • [TBD]

    share of those findings that produced no symptoms

  • [TBD]

    median time from start of monitoring to first significant finding

[TBD: each figure needs its definition and period before launch: what counts as critical and what counts as significant, over what date range, and in which markets.]

Impact report

The 59,297-patient cohort report

What we found across the monitored cohort: the share of studies with a critical or significant finding, how those findings broke down by rhythm class, and how long into monitoring they appeared. [TBD: to be written and approved before publishing]

Report coming soon

Success stories

Real studies from the platform, told the same way each time: what was asked, what was found, what the clinician did, and how the patient ended up.

Showing all 10

  • Pause · 5-day monitoring

    7 s

    Nothing on day one or two. On day three, a seven-second pause.

    A 77-year-old man with occasional palpitations. During an episode of palpitations and dizziness on day three, the recording showed typical flutter waves followed by a compensatory pause of seven seconds. An interim report reached the treating cardiologist within five minutes. He recommended a pacemaker, it was implanted, and the patient was stabilised.

    Dr Sony Agarwal, March 2023 [TBD: confirm consent to publish and whether the centre may be named]

  • Atrial fibrillation

    Slot 02

    Awaiting case

    Paroxysmal AF found in a patient monitored for unexplained dizziness.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Ventricular

    Slot 03

    Awaiting case

    A run of VT escalated to the on-call team while the patient was still wearing the sensor.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Screening

    Slot 04

    Awaiting case

    A finding in a corporate screening programme, in someone with no symptoms.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Pause & block

    Slot 05

    Awaiting case

    High-grade AV block caught overnight on extended monitoring.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Atrial fibrillation

    Slot 06

    Awaiting case

    AF burden measured before and after a change in therapy.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Screening

    Slot 07

    Awaiting case

    A community camp case where a single lead was enough to act on.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Ventricular

    Slot 08

    Awaiting case

    Ectopy burden that changed a treatment decision rather than triggering one.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Pause & block

    Slot 09

    Awaiting case

    Sinus node dysfunction found after a normal 24-hour Holter.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

  • Atrial fibrillation

    Slot 10

    Awaiting case

    A post-stroke patient in whom AF appeared weeks into monitoring.

    [TBD: case needed: what was asked, what was found, what the clinician did, what happened to the patient]

One published, nine slots open. New cases are added weekly.

Publications

Featured · Peer-reviewed2023

Screening of cardiac rhythm disorders in women working in the information technology sector using continuous ambulatory wireless cardiac monitoring

Indian Journal of Cardiovascular Disease in Women, 2023;8:11–17 · Kampally M, Bala S, Agarwal S et al. [TBD: confirm full author list and page range]

109 women aged 21 to 58 wore a wireless monitor for 48 hours, 24 on a working day and 24 on a rest day, each acting as her own control. Everyone with known coronary disease, hypertension, diabetes, thyroid disorder, anaemia, pregnancy or hormonal therapy was excluded before enrolment, so these are findings in people with no reason to be looked at.

had a clinically significant arrhythmia
4.58%
of those women were under 30
4 of 5
odds of prolonged QTc with higher work stress
3.66×
Second-degree AV block, Mobitz I
2
Atrial tachycardia
2
Sinus pauses
1
Premature complexes, not clinically significant
31
QTc, working day against rest day
450 vs 430 ms

Read the full article (opens in a new tab) [TBD: point this at the article's new home or the journal DOI before launch]

  • White paper—

    Slot 02

    Awaiting publication

    Every entry follows the same shape: what was studied, in whom, over what period, what was found, and a link to the full text. Three headline figures, then the detailed findings.

    headline figure
    —
    headline figure
    —
    headline figure
    —
  • Peer-reviewed—

    Slot 03

    Awaiting publication

    Journal, year, volume and author list on one line. Summary in three or four sentences, always naming the cohort and the period.

    headline figure
    —
    headline figure
    —
    headline figure
    —
  • Abstract—

    Slot 04

    Awaiting publication

    Conference abstracts and posters use the same card, with the meeting named in place of the journal.

    headline figure
    —
    headline figure
    —
    headline figure
    —
  • ValidationPlanned

    Vector's own algorithm validation

    Not yet published

    [TBD: Vector validation] Per-class sensitivity and specificity against adjudicated ground truth, false-positive burden per patient-day, analysable time, and cohort composition by market. It should include the numbers that are less flattering. Any accuracy figure carries its denominator.

    sensitivity, per class
    —
    false positives per 1,000 patient-days
    —
    analysable time
    —
  • White paper—

    Slot 06

    Awaiting publication

    Adding a publication is one card. The grid reflows on its own and nothing above or below it needs touching.

    headline figure
    —
    headline figure
    —
    headline figure
    —

Literature

Showing all 6

01

Arrhythmia is intermittent, so a short recording misses most of it.

In 1.1 million patch recordings, around 60% of arrhythmias appeared only after the first 48 hours, and the median time to first detection was three and a half days. Frequent symptoms did not shorten it.

Battisti AJ et al., Heart Rhythm, 2025. 1,100,337 monitors (opens in a new tab). Zio long-term continuous monitor; several authors iRhythm-affiliated.

Truncating the same recordings to 24 hours dropped detection of any arrhythmia from 62.2% to 43.9%, and of symptomatic arrhythmia from 9.7% to 4.4%. Half of first symptom-triggered arrhythmias arrived after 48 hours.

Turakhia MP et al., Am J Cardiol, 2013;112(4):520–524 (opens in a new tab). 26,751 consecutive referred patients.

Symptoms are a poor guide to when to look. Symptom–rhythm correlation was 18.3% overall, above 30% only for AF and isolated ectopy.

Battisti AJ et al., Heart Rhythm, 2025.

02

Diagnostic yield rises with how long you monitor.

Against three years of continuous implantable monitoring in the same people, a single 10-second ECG found 1.5% of the atrial fibrillation present. A 24-hour recording found 11%, 48 hours 13%, 72 hours 15%, seven days 21%, thirty days 34%.

Diederichsen SZ et al., Circulation, 2020;141(19):1510–1522 (opens in a new tab). 590 people aged 70+ with a stroke risk factor; 659,758 monitored days. A simulation run on real continuous data, in a screening population, for AF only.

Worn simultaneously on the same patients, a 14-day patch recorded 96 arrhythmia events against 61 for a 24-hour Holter. In the overlapping first 24 hours the Holter was the better recorder. The advantage is duration, not the sensor.

Barrett PM et al., Am J Med, 2014;127(1):95.e11–95.e17 (opens in a new tab). 146 patients, prospective simultaneous wear.

After cryptogenic stroke, continuous monitoring found AF in 12.4% by twelve months and 30.0% by three years, against 2.0% and 3.0% under conventional follow-up. Median time to first detection was 8.4 months.

Sanna T et al., N Engl J Med, 2014;370:2478–2486 (opens in a new tab) and Brachmann J et al., Circ Arrhythm Electrophysiol, 2016;9(1):e003333 (opens in a new tab). CRYSTAL-AF, 441 patients, randomised.

03

Most of what matters produces no symptoms at all.

Of people whose AF was found by an implanted monitor, 90.2% had no symptoms when it began and 86.8% stayed symptom-free throughout. Median AF burden was 0.13% of monitored time.

Diederichsen SZ et al., J Am Coll Cardiol, 2019;74(22):2771–2781 (opens in a new tab). LOOP, 590 people aged 70+, median 40 months.

After stroke attributed to large or small vessel disease, 88% of all AF episodes recorded by the device were asymptomatic.

Bernstein RA et al., JAMA Neurology, 2023;80(12):1277–1283 (opens in a new tab). STROKE-AF, 492 patients. Medtronic-sponsored.

In pacemaker patients with no AF history, 10.1% had subclinical atrial tachyarrhythmia within three months, and it carried a 2.5-fold risk of stroke or systemic embolism.

Healey JS et al., N Engl J Med, 2012;366(2):120–129 (opens in a new tab). ASSERT, 2,580 patients aged 65+.

04

Risk concentrates in populations you can name, which is what makes screening tractable.

In 617,000 people with type 2 diabetes against 2.3 million matched controls, the excess was largest for conduction disease rather than AF: sinus node disease, AV block or pacemaker implantation 1.40, intraventricular block 1.23, atrial fibrillation 1.17. With every cardiometabolic risk factor in target range the AF excess fell to 1.09.

Rawshani A et al., Scientific Reports, 2023;13 (opens in a new tab). Swedish National Diabetes Register, 2001–2019. Observational: association, not causation.

Chronic kidney disease raises new-onset AF risk by about half (HR 1.47). Alcohol shows a clean dose response, from 1.08 at one drink a day to 1.47 at five. Hypertension carries an odds ratio of about 1.4 to 1.5.

Shang W et al., PLoS ONE, 2016 (opens in a new tab) (400,189 participants) · Larsson SC et al., J Am Coll Cardiol, 2014 (opens in a new tab) (79,019 participants) · Benjamin EJ et al., JAMA, 1994 (opens in a new tab) (Framingham, 38 years).

People of South Asian origin present with a first myocardial infarction around six years younger than participants elsewhere, at a mean of 53.0 against 58.8 years, on an almost identical risk-factor profile.

Joshi P et al., JAMA, 2007;297(3):286 (opens in a new tab). INTERHEART, 1,732 South Asian cases across five countries. Case-control: this is the age of enrolled cases, not a population incidence shift.

05

When a sudden death is examined, the mechanism is usually electrical and the person usually had no diagnosis.

Of 525 autopsied sudden cardiac deaths, 55.8% were arrhythmic in mechanism, and 57% occurred in people with no known cardiac disease.

Tseng ZH et al., Circulation, 2018 (opens in a new tab). POST SCD, countywide medical-examiner surveillance of 20,440 deaths in San Francisco.

Only about one in five out-of-hospital cardiac arrests presents in a shockable rhythm, and survival to discharge is 24% for those against 3% for the rest.

Gräsner J-T et al., Resuscitation, 2020;148 (opens in a new tab). EuReCa TWO, 37,054 arrests across 28 European countries.

Screening for AF in rural western India found it in 1.6% of adults aged 40 and over, rising from 0.6% at 40–55 to 5.6% above 75. Detection used a handheld single-lead device on three separate days rather than a single resting ECG.

Soni A et al., Int J Cardiol, 2018 (opens in a new tab). SMART-India, 2,074 participants across 50 villages.

06

Machine analysis of ambulatory ECG now outperforms human reading at scale.

In a 14,606-patient adjudicated comparison, AI reporting reached 98.6% sensitivity for critical arrhythmias against 80.3% for certified technicians, with 3.2 false negatives per 1,000 patients against 44.3, and a higher false-positive rate of 12 against 5 per 1,000 patient-days.

Johnson LS et al., Nature Medicine, 2025. DeepRhythmAI / MARTINI. Independent research on another platform, cited as category evidence and not as a Vigocare result.

Where the evidence does not support us, and we will not pretend otherwise

Finding more arrhythmia is not the same as improving outcomes. The LOOP trial tripled AF detection and more than doubled anticoagulation, and still did not significantly reduce stroke or systemic embolism (HR 0.80, p = 0.11). ASSERT found stroke risk was significant only for episodes lasting more than 24 hours. Every claim on this page is a detection claim.

Reading around the claims

Six claims, twenty citations. New evidence is added under the claim it supports.

Questions

The questions clinicians actually ask us.

Short answers, each one backed by the science. Where the evidence is unsettled, the answer says so.

My patient has symptoms every day. Is 24 hours enough?
No, and this is the most common assumption worth testing. Across 1.1 million recordings, 64% of arrhythmias in patients with daily symptoms still appeared after the first 48 hours, and the adjusted odds of detection did not differ by how often patients felt symptoms. Median time to first detection was 3.5 days in daily-symptom patients against 3.0 days in the rest.

Battisti AJ et al., Heart Rhythm, 2025.

How much does going from 24 hours to 7 or 14 days actually add?
In the same people measured against three years of continuous monitoring, AF detection rose from 11% at 24 hours to 21% at seven days and 34% at thirty. In a simultaneous-wear comparison, a 14-day patch recorded 96 arrhythmia events against 61 for a 24-hour Holter on the same patients. Note that during the overlapping first day the Holter recorded more, so the gain is duration rather than the sensor.

Diederichsen SZ et al., Circulation, 2020 · Barrett PM et al., Am J Med, 2014.

If I find more atrial fibrillation, do I prevent more strokes?
Not on the current evidence, and we will not claim otherwise. The LOOP trial tripled AF detection and more than doubled anticoagulation, and the reduction in stroke or systemic embolism was not statistically significant (HR 0.80, 95% CI 0.61–1.05). ASSERT found the stroke association held only for episodes lasting more than 24 hours. Detection and benefit are different questions.

Svendsen JH et al., The Lancet, 2021 (opens in a new tab) · Van Gelder IC et al., Eur Heart J, 2017 (opens in a new tab).

Single lead or twelve. What am I giving up?
One lead is enough to establish rhythm, which is what makes screening affordable at population scale. Multi-lead gives morphology, axis and conduction detail, which a specific clinical question sometimes turns on. The platform analyses both against the same classification standard and issues the same report format, so the choice stays clinical.

Platform capability. [TBD: per-class performance by lead count to be published with Vector validation]

How does AI reading compare with a certified technician?
In a 14,606-patient adjudicated comparison on another platform, AI reached 98.6% sensitivity for critical arrhythmias against 80.3% for technicians, with 3.2 false negatives per 1,000 patients against 44.3. The trade is a higher false-positive rate, 12 against 5 per 1,000 patient-days. That is category evidence, not our result; ours belongs under Publications and is not yet published.

Johnson LS et al., Nature Medicine, 2025.

Is a pause always significant?
No. Context decides: how long, whether the patient was asleep, what rhythm preceded and terminated it, and whether symptoms coincided. This is why every finding on the platform opens to the beats behind it rather than arriving as a verdict, and why the report carries the preceding and terminating beats alongside the measurement.

Platform behaviour, not a literature claim.

Six answered. Send us the question your team keeps asking and it goes on this list.